Quick Guide · Rauland (AMETEK)

Nurse call (Rauland): etiquette & escalation

  1. Answer every call promptly, even if the answer is "I will send your nurse." Silence reads as neglect.
  2. Speak through the pillow speaker like you are at the bedside: introduce yourself and say what happens next.
  3. Cancel the call at the bedside, in the room — never from the console alone. The visit is the point.
  4. Escalate up the chain when a request is clinical, urgent, or waiting too long: nurse, then charge, then provider, per policy.
  5. Use priority and code buttons only for their real purpose. Alarm fatigue is a safety problem.
  6. If the system faults — a dead station, a stuck light — put in the work order and tell the charge nurse the same shift.
Step-by-step fix

Fix: Nurse call — call light will not clear

A call light that will not clear is usually a room station that has not been reset at the bedside, a pillow speaker half-seated in its socket, or a fault the system is honestly reporting. Clear it in the room, not from the desk.

  1. Go to the room. Most stations only cancel at the bedside cancel button or station — press it firmly once and watch the light.
  2. Reseat the pillow speaker cord in its wall socket until it clicks; a cord hanging by one pin keeps the call alive, and patients cannot always tell you.
  3. Check the bathroom pull cord and the bed cord too — a second device in the same room can be holding the call open.
  4. If the dome light stays lit with everything reseated and cancelled, it is a system fault: tell your charge nurse and put in the work order for biomed or facilities the same shift.
  5. Until it is fixed, round on that room more often and say so to the patient — a broken light means they cannot reach you, and they should hear the plan from you.
Step-by-step fix

Fix: Nurse call — pillow speaker has no sound

When a patient says “I pressed it and nobody came,” check the speaker before the system: pillow speakers live rough lives, and a failed speaker makes a working system look broken from the bed.

  1. Test from the bed: press the call, then speak through the speaker yourself. Check the volume buttons on the pillow speaker — they get bumped to zero constantly.
  2. Swap the pillow speaker with a known-good one from an empty room if your unit stocks spares — the fastest way to prove it is the speaker and not the wall station.
  3. Inspect the cord end and the wall socket for bent pins; reseat firmly until it clicks.
  4. If the wall station itself stays silent with a good speaker, it is a work order: charge nurse notified, biomed or facilities ticket in, same shift.
  5. Set the patient up with a hand bell or closer rounding until it is fixed, and note the fault per your unit’s habit — the next shift should not rediscover it at 2 a.m.
On every system
Step-by-step fix

Fix: When the system is DOWN — downtime basics

Every system you rely on will have a down day. Downtime is a drill you already know: care continues on paper, times get written down, and recovery goes smoothly for the nurse who documented like it mattered — because it does.

  1. Confirm it is really down: check one other workstation or ask a neighbor, then notify your charge nurse — they own the downtime call.
  2. Switch to your facility’s downtime forms and downtime med records. Know where the paper lives before you need it; if you do not, ask now.
  3. Write times on everything: meds given, vitals, events. Recovery charting later lives or dies on those times.
  4. Call the IT help desk and note a ticket number if your facility uses them — and use the downtime viewer or read-only access if your facility provides one.
  5. When systems return, back-chart exactly what the paper says, marked as downtime entries per policy — never reconstruct from memory. Hand the paper to your charge nurse at recovery.
Step-by-step fix

Fix: Workstation on wheels — will not wake

A dead WOW is usually a battery story: carts live hard lives, get unplugged by housekeeping, and quietly drain against the wall. Power first, panic never.

  1. Plug the cart into a wall outlet and give it two full minutes — a deeply drained cart often shows nothing at all until it sips some power.
  2. Check the basics: the monitor power button, the PC power button, and the cart’s own power switch or strip, which hides near the base.
  3. Hold the PC power button for ten seconds to force it fully off, wait ten more, then power on fresh.
  4. Swap to a working cart so your med pass and charting do not wait on one machine — borrow from a neighbor and trade back later.
  5. Tag the dead cart per your unit’s habit and tell your charge nurse; biomed or IT owns cart batteries, and an untagged dead cart just gets pushed to the next nurse.

Fix a problem on Rauland Responder

Pick what it is doing and follow the steps. Fixes here are guided, step by step — SysNurse cannot reach into your workstation, and no app should. Never type your work password anywhere except Rauland Responder’s own official sign-in, and never share patient information in a fix request.